PROGRAMMING MODE continued
Level II Programming - P Values
Level II Programming parameters can be adjusted to fine-tune
the conditioner's operation. The parameters are accessible
by pressing and holding the UP and DOWN buttons until the
control displays a "P" value.
NOTE: The control must be in the home position to change
settings. See Table for Level II parameters. Typically
the Level II parameters will not need to be adjusted as
the default settings accommodate most applications.
Contact your water treatment professional before
attempting any programming.
Description
P9
Units of Measure
P10
Clock Mode
P11
Service Interval
Resin Tank Sensor
P12*
Placement
Disable Resin Tank
P13
Sensors
P14
Refill Rate
P15
Draw Rate
P16
Flow sensor select
K-factor or Pulse
P17
equivalent
P18
Tank in Service
P19
Cleaning Cycle Interval
*The control will automatically adjust the Hardness Setting P8 when the sensors in the resin tank detect a hardness front passing. This automatic
adjustment to the hardness setting may result in the system passing hard water near the end of the service cycle if the resin tank sensor
placement setting P12 is wrong. The sensor placement setting P12 must be reduced to eliminate the problem. Reducing the Capacity Setting P7
or increasing the Hardness setting P8 will only produce a temporary solution.
NOTE: (1) Default selected with initial setting value.
(2) Facotry Default is "0" for North America units and "1" for World units.
12 •
FLECK 9100TS Upflow
Minimum
Range
Default
Increments
0-1
1
0-3
1
0-99
1
60-01
1
0-1
1
1-700
1
1-700
1
1-4
1
0.01-99.99
0.01
1-2
1
0-100
1
Units
(2)
0 = US
0 = 12 hour clock: flow rate displayed
1 = 24 hour clock: flow rate displayed
(2)
2 = 12 hour clock; Time of Day displayed
3 = 24 hour clock; Time of Day displayed
0 = Dissabled. Number of days per month is fixed
0
Months
at 30.
Expressed as a percentage of resin bed capacity
20
% of Capacity
remaining after lowest set of pins.
0 = Resin Tank Sensors Enabled
0
1 = Resin Tank Sensors Disabled
(1)
gpm x 100
Used with salt amount to calculate refill time.
(1)
gpm x 100
Used with salt amount to calculate draw time.
1 = 1" Autotrol turbine
2 = 2" Autotrol turbine
3 = User defined K-factor
4 = Fleck 3/4" Paddle
4
5 = Fleck 3/4" Turbine
6 = Fleck 1" Paddle
7 = Fleck 1"/1-1/2" Turbine
8 = Fleck 1-1/2" Paddle
9 = Meter Factor
K-factor P16 = 3;
0.01
Pulse Equivalent P16 = 9
1
Select the Tank in Service.
Number of standard regeneration cycles
6
between cleaning regeneration cycles.
Notes
1 = Metric