USER PROGRAMMING continued
• Value is derived from the system's resin volume input and
salt amount input.
• To override capacity on the control, press SET to make the
default capacity flash. Use the UP and DOWN buttons to
increment to the desired capacity.
• Press SET to accept the setting and advance to the next
parameter.
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Figure 15
Step 8: Enter Hardness
• Enter inlet water hardness at installation site.
• Default hardness setting is 10 grains (170 ppm).
• To change hardness, press SET to make the setting flash.
Use the UP and DOWN buttons to scroll to the desired
hardness.
• Press SET to accept the entered hardness value.
• The control will return you to the normal operation mode.
Initial programming is now complete. The control will return
to normal operation mode if a button is not pushed for 30
seconds.
SU
Time & Day
Regen Time & Day
Backwash Time
Capacity
Hardness
Figure 16
In Service Display
SU MO TU
Time & Day
Regen Time & Day
Salt Amount
Capacity
Hardness
SU MO TU
Time & Day
Regen Time & Day
Salt Amount
Capacity
Hardness
10 •
FLECK 9100TS Upflow
WE TH FR SA DAYS
KG
MO TU
WE
TH
FR
SA DAYS
WE TH FR SA DAYS
WE TH FR SA DAYS
Figure 17
The display shows the number of the tank in service (small
digit next to CPH position). The display also alternates between
Capacity Remaining and Flow Rate (faucet icon) for the tank in
service.
NOTE: The Regen icon is steady on when in regeneration.
NOTE: The faucet icon is displayed when there is flow. The
display will show the faucet icon when the flow rate is
displayed, even if the flow rate is zero. The faucet icon
will turn off when the capacity is displayed.