Fleck 9100TS Upflow Service Manual page 14

Smart softener
Table of Contents

Advertisement

PROGRAMMING MODE continued
Level IV Viewing History - H Values
Historical information can be viewed by pressing the SET and
DOWN buttons simultaneously, with the 9100TS control in the
home position. Release both buttons when the control displays
an "H" value. Press the UP or DOWN buttons to navigate to
each setting.
H#
Description
H0*
Initial Setting Value
H1
Days since last regeneration
H2
Current Flow Rate
H3
Water used today in gallons or m
Regeneration
H4
Water used since last regeneration in gallons or m
H5*
Total water used since reset in 100s
H6*
Total water used since reset in 1,000,000
H7
Average usage for Sunday in gallons or m
H8
Average usage for Monday in gallons or m
H9
Average usage for Tuesday in gallons or m
H10
Average usage for Wednesday in gallons or m
H11
Average usage for Thursday in gallons or m
H12
Average usage for Friday in gallons or m
H13
Average usage for Saturday in gallons or m
H14
Average service cycle
H15*
Peak Flow Rate
H16
Day and Time of Peak Flow Rate
H17*
Months since service
H18
Number of Low Salt Alarms
H19
Number of Reduced Capacity Alarms
H r
Number of regenerations since last serviced
*H0, H5, H6, H15, H17 values can be reset by pressing and holding
14 •
FLECK 9100TS Upflow
Cubic Feet or Liters
Depends on turbine used
since Time of
0-131,070 gallons or 0-1,310.7 m
3
0-131,070 gallons or 0-1,310.7 m
3
0-999900 gallons or 0-9999m
4,294 x 10
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-131,070 gallons or 0-1,310.70 m
3
0-200 gpm or 1000Lpm
Time and day that peak flow occurred
Range
Resin Volume, Holding SET for 3 seconds
0-255
3
3
Holding SET key for 3 seconds will reset
3
gallons or 4,264 x 10
m
Holding SET key for 3 seconds will reset
6
4
3
3
3
3
3
3
3
3
0-255 days
Holding SET key for 3 seconds will reset
0-2184 months
Holding SET key for 3 seconds will reset
0-65536
0-65536
0-65536
Holding Set key for 3 seconds will reset Hr to zero.
for 3 seconds while the value is being displayed.
Notes
will reset control to factory defaults
H5 and H6 to zero.
H5 and H6 to zero.
Last 4 Regens
H15 to zero.
H17, H18 and H19 to zero.