PROGRAMMING MODE

Programming Overview
The 9100TS control includes multiple program levels that
allow water treatment professionals to customize the system
for many water conditions. Additionally, historical data can be
viewed allowing quick and easy troubleshooting. In most cases
Level I Programming is all that is required to set up the water
conditioning system for proper operation. A brief description of
each program level is listed below.
Level I - Used to program control for normal applications.
Level II (P-Values) - Allows the installer to customize
programming for non-standard applications including
parameters that are also programmable in Level I.
Level III (C-Values) - Allows the installer to adjust length of
select cycles for non-standard applications.
Level IV History (H-Values) - Allows access to historical
information for troubleshooting the system.
NOTE: If a button is not pushed for thirty seconds, the control
returns to normal operation mode.
Level I Programming
The 9100TS control can be quickly programmed by following
the sequential procedure in the section "Placing Water
Conditioning System Into Operation". Level I Program
parameters are those that can be accessed by pressing the
UP or DOWN buttons. Step-by-step instructions are shown on
previous page.
• Resin Volume Setting: Set to match the volume (cubic
feet) of resin in the mineral tank.
• Time of Day: Includes PM indicator. Can be set to display
as a 24-hour clock. See Level II programming.
• Day of Week: Set to actual day of the week.
• Time of Regeneration: Fully adjustable. Default is 2:00 AM.
• Days Override: Range 0.5 to 30 days. Leave at 0 to disable.
• Salt Dosage: Set at pounds of salt per cubic foot of resin
in the conditioner tank.
NOTE: When the control is set up for a twelve-hour clock a PM
indicator will illuminate when the displayed time is in
the PM hours. There is no AM indicator.
Programming the Lockout Feature
All Level I parameters can be locked out when the control is in
Level II Programming. Simply press the REGEN button during
Level II Programming and a lock icon will appear indicating
that the specific setting has been locked out. When locked
out, the setting cannot be adjusted in Level I Programming. To
disable the Lock Out feature, press the REGEN button when in
Level II. The lock icon will not be displayed.
Injector and Brine Line Flow Control Sizing
Tank Diameter
Resin Volume
(inches)
US
8
0.75
9
1.00
9
1.25
10
1.50
12
2.00
Salt Setting
The default P6 salt setting is set at 9 lbs/cu ft (110 g/l). Under
normal circumstances this setting will provide the correct
system capacity. The exchange capacity setting P7 will
automatically change when the salt setting P6 is changed.
Exchange
Salt Setting
Capacity
lbs/cu ft
grains/cu ft
3
14631
4
17799
5
20682
6
23279
7
25592
8
27619
9*
29361
10
30818
11
31990
12
32877
13
33478
14
33795
15
33826
*Default Setting.
Injector
BLFC
Metric
20
#000
0.125
30
#000
0.125
35
#000
0.125
45
#000
0.125
60
#00
0.5
Exchange
Salt Setting
Capacity
grams/liter
grams/liter
50
34.4
60
38.9
70
43.2
80
47.3
90
51.1
100*
54.6
110
57.9
120
60.9
130
63.7
140
66.2
150
68.5
170
72.2
200
76.0