CONTROLLER FEATURES

Display Icons & Cursors
14
13
Regeneration Time
15
12
26
25
NOTE: In normal operation and during programming, only a
few of the icons are actually displayed.
1. This cursor is displayed when the days between
regeneration are being programmed (used with .5 to 30 day
regeneration programming).
2. One of these cursors is displayed to indicate which day will
be programmed into the controller.
3. "PM" indicates that the time displayed is between 12:00
noon and 12:00 midnight (there is no AM indicator). PM
indicator is not used if clock mode is set to 24-hour.
4. When "MIN" is displayed, the value entered is in minute
increments.
5. When g/L is displayed, the value for regenerant amount
entered is in grams/Liter of resin.
6. When "Kg" is displayed, the value entered is in kilograms or
kilograins.
7. Four digits used to display the time or program value. Also
used for error codes.
8. Colon used as part of the time display.
9. Locked/unlocked indicator. In Level I Programming this
is displayed when the current parameter is locked-out.
It is also used in Level II Programming to indicate if
the displayed parameter is locked (icon flashes) when
controller is in Level I.
10. When "x2" is displayed, a second regeneration has been
called for.
11. The recycle sign is displayed (flashing) when a regeneration
at the next time of regeneration has been called for. Also
displayed (continuous) when in regeneration.
12. The display cursor is next to "SALT AMOUNT" when
programming the amount of regenerant.
13. The display cursor is next to "REGENERATION TIME" when
programming the time of regeneration and the days of
regeneration.
14. The display cursor is next to "TIME/DAY" when
programming the current time and day.
15. The hourglass is displayed when the motor is running. The
piston should be moving.
16. These cursors appear next to the item that is currently
displayed.
6 •
FLECK 9100TS Upflow
9
16
SU MO TU
Time/Day
Salt Amount
11
C
Capacity
Hardness
24
23
10
8
WE TH FR SA DAYS
x2
P
H
20
21
22
17. X100 multiplier for large values.
18. When Lbs/ft
is displayed the value for regenerant amount
3
entered is in pounds/cubic foot of resin.
19. Faucet is displayed when the current flow rate is displayed.
Control may show the faucet and "0", indicating no flow.
20. Maintenance interval display turns on if the months in
service exceed the value programmed in P11.
21. Displays the tank in service during normal operating mode.
Used with #22, #23 and #24 in programming mode or
regeneration.
22. History Values (H). The number displayed by #21 identifies
which history value is currently displayed.
23. Parameter (P). Displayed only in Level II Programming.
The number displayed by #21 identifies which parameter is
currently displayed.
24. Cycle (C). The number displayed by #21 is the current cycle
in the regeneration sequence.
25. Hardness setting.
26. Capacity display—shows estimated system capacity.
2
7
1
3
PM
MIN
4
g/L
5
KG
6
x100
17
3
Lbs/ft
18
19