Fleck 9100TS Upflow Service Manual page 9

Smart softener
Table of Contents

Advertisement

USER PROGRAMMING continued
Step-by-Step Instructions
Step 1: Program System Size
This step may have been performed by your system's OEM
manufacturer. In this case, proceed to step 2.
NOTE: Capacity is the result of the amount of media in the
tank and the salt setting. The default capacity will be
changed by selecting a different regenerant setting.
• Input system size – media volume – in cubic feet (liters).
• Use UP and DOWN buttons to scroll through resin volume
choices.
• Choose the nearest volume to your actual system size.
• Press SET to accept the system size you've selected.
NOTE: If the controller was incorrectly set to the wrong
size, press the DOWN button and SET button for five
seconds to display resin volume in "HO". Press and
hold the SET button for five seconds to reset the
controller. Use the UP or DOWN buttons to increment
the display to the correct resin volume. Press SET.
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Figure 9
Step 2: Program Time of Day
• While "12:00" is blinking, set the correct time of day.
• Use the UP and DOWN buttons to scroll to the correct
time of day.
• "PM" is indicated, "AM" is not indicated.
• Press SET to accept the correct time of day and advance
to the next parameter.
SU MO TU
Time & Day
Capacity
Hardness
Figure 10
Step 3: Set Day of Week
• Press SET to make the arrow under "SU" flash.
• Use the UP and DOWN buttons to advance the arrow until
it is under the correct day of week.
• Press SET to accept and advance to the next parameter.
SU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
WE TH FR SA DAYS
WE TH FR SA DAYS
FR
MO TU
WE
TH
SA DAYS
Figure 11
Step 4: Set Regen Time
• 2:00 (AM) is the default time of regeneration. To accept
this time, press the DOWN button to move to step 5.
• To change the regen time, press SET – causing "2:00" to
flash.
• Use the UP and DOWN buttons to advance to the desired
regen time.
• Press SET to accept the time and advance to the next
parameter.
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Figure 12
Step 5: Set Calendar Override
• Set number of days for calendar override.
• "0" days (disabled) is the default for calendar override.
• Days can be adjusted from ½ (.5) to 30 days.
• To change, press SET to make the "0" flash.
• Use the UP and DOWN buttons to change to the number
of days desired. Press SET to accept the regen frequency,
and advance to the next cycle.
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Figure 13
Step 6: Amount of Regenerant used per Regeneration
• Set desired regenerant amount.
• Default setting is 9 lbs/cubic feet (120 gm/l).
• To change salt setting, press the SET button and use the
UP and DOWN buttons to change to the desired setting.
• Press SET to accept the setting and advance to the next
parameter.
SU MO TU
Time/Day
Regeneration Time
Salt Amount
Capacity
Hardness
Figure 14
Step 7: Estimated Capacity
• System capacity is displayed in total kilograins or
kilograms of hardness removed before a regeneration is
necessary.
WE TH FR SA DAYS
WE TH FR SA DAYS
WE TH FR SA DAYS
3
Lbs/ft
• 9
FLECK 9100TS Upflow