TROUBLESHOOTING continued
9100TS Controller
Problem
ERR 1 is displayed.
ERR 3 is displayed.
ERR 4 is displayed.
ERR 6 is displayed.
Check Salt Light is displayed - Press
the regen button to turn off the check
salt light.

9000/9100 METER FLOW DATA

9100 Meter Flow Data
26 •
FLECK 9100TS Upflow
Cause
Program settings have been corrupted.
Controller does not know the position of the
piston. Cam should be rotating to find Home
position.
Cam is not turning during ERR 3 display.
Cam is turning more than five minutes to
find Home position.
Regeneration starts but control shows Err3
before completing regeneration.
Hardness front detected with no water flow.
Conductivity sensors' reading out of range.
Defective sensors or no sensors are
connected.
No regenerant draw or insufficient
regenerant detected during regeneration.
Solution
Press any key and reprogram Level I settings.
Wait five minutes for the controller to return to Home
position. The hourglass should be flashing on the
display indicating the motor is running.
Check that motor is connected. Verify that motor wire
harness is connected to motor and controller module.
Verify that Home switch is connected and in place.
Verify that motor gear has engaged cam gear.
If everything is connected, try replacing in this order:
1. Home Switch, Wire Harness, Motor
2. Controller
Verify that Home Switch is in place and connected to
wire.
If motor continues to rotate indefinitely, replace the
following components in this order:
1. Home Switch, Wire Harness, Motor
2. Controller
Check that motor is connected. Verify that motor wire
harness is connected to motor and controller module.
Verify that Home Switch sensor is connected and in
place.
Verify that motor gear has engaged cam gear.
If everything is connected, try replacing in this order:
1. Home Switch, Wire Harness, Motor
2. Controller
Check that meter cable is connected and operational.
Service meter. Check meter for debris and/or replace
as necessary.
Can program P13 = 1 to disable conductivity sensors.
Check which tank is in service and check if the sensors
have been connected properly. If already connected,
replace conductivity sensor probes with new ones.
Ensure salt/regenerant is available.
Check for regenerant draw.
Inspect regeneration line for leaks.