Electrical Connection - Fleck 9100TS Upflow Service Manual

Smart softener
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS continued
Brine Line Connection
The brine line from the brine tube connects to the valve. Make
certain the connections are hand tightened. Be sure that the
salt line is secure and free from air leaks. Even a small leak
may cause the salt line to drain out, and the softener will not
draw salt from the tank. This may also introduce air into the
valve causing problems with valve operation.
To install the brine line:
1. Inside the salt tank, remove the cap from the large cylinder
to gain access to the connection.
2. Be sure the brass insert is in the end of the brine tubing.
Insert the tubing through the opening in the tank.
3. Push the tubing into the plastic nut. Slowly unscrew the nut
until the tubing moves into the connection. The tubing will
hit bottom.
Figure 6
NOTE: Once the tubing has been pushed into the nut it cannot
be pulled out. The nut will need to be removed. See
Figure 6 for correct assembly.
4. Hand tighten the nut until the connection is tight.
5. Make compression fitting connection between brine line
and valve (Figure 7).
Figure 7

Electrical Connection

This valve and control are for dry location use
WARNING:
only unless used with a Listed Class 2 power
supply suitable for outdoor use.
The controller operates on 24-volt alternating current power
supply. This requires use of the supplied AC adapter included
with your system.
AC Adapter
Make sure power source matches the rating printed on the AC
adapter.
NOTE: The power source should be constant. Be certain
the AC adapter is not on a switched outlet. Power
interruptions longer than 8 hours may cause the
controller to lose the time setting. When power is
restored, the time setting must then be re-entered.
9100TS Control Operation
Power Loss Memory Retention
The 9100TS control features battery-free Time of Day and Day
of Week retention during temporary loss of power. A super
capacitor is designed to keep time for 8 to 24 hours depending
on the installation. If the super capacitor is exhausted the
9100TS control will display four dashes (- - : - - ) immediately
upon power up. The Time of Day and Day of Week must be
reset.
All other programmed parameters are stored in the static
memory and are retained.