To extract a Fan Unit
1. Using two fingers, push both latch releases towards each other simultaneously while pulling
the fan module out of the switch. As the fan unseats, the fan status indicator will turn off.
To insert a FAN Unit:
1. Make sure the mating connector of the new unit is free of any dirt and/or obstacles.
2. Insert the fan unit by sliding it into the opening until slight resistance is felt. Continue press-
ing the fan unit until it seats completely.
The green fan status indicator should light. If not, extract the fan unit and reinsert it.
After two unsuccessful attempts to install the fan unit, power off the switch before
attempting any system debug.
3.14

Switch Shut Down Procedure

To shut down the switch run the command:
Reload halt [noconfirm]
The switch cannot be restarted remotely!
To restart the switch you must physically go to the switch and unplug and plug
in the power cord.