Air Flow; Qsfp Cable Power Budget Classification; Table 8: Air Flow Direction - Mellanox Technologies SwitchX User Manual

36-port qsfp 40gb/s ethernet system
Table of Contents

Advertisement

Rev 1.3
3.2

Air Flow

These switches can come with two air flow patterns. The two patterns are:
• Connector side inlet to power side outlet
• Power side inlet to connector side outlet
The air flow is specified in the product model number. See "Mellanox Part Numbering Legend"
on page 10. On the PS unit and fan modules the air flow direction can be seen on the power side
panel.
All PS units must have the same air flow as the fan module.
Table 8 - Air Flow Direction
Direction
3.3

QSFP Cable Power Budget Classification

All SwitchX QSFP switches are designed for active cables with a max power per module of 2W.
Typical power per port is 1.3W.
22
Mellanox Technologies
OPN
Label
Designation
R
F
Basic Operation and Installation
Description
Connector side inlet to power side
outlet
Power side inlet to connector side
outlet

Advertisement