Repairs
2. Pull the tension cord holder upwards (1). Fix in the groove of the basis carrier
(2).
3. Slowly close the door. The cord system attaches itself automatically to the door
hinge when closing the door.
2016-03-02 / DIS 840_58300000176874_ara_en_c
6.42.5
Adjusting the door opening module
Prerequisite:
Toe panel has been removed.
► Tighten and loosen the screws to vary the tension of the tension cord until the
required tension is reached.
Copyright by BSH Hausgeräte GmbH
Adjust the door opening with the adjusting screws in such a way
that the door automatically opens to 10 cm.