Replacing The Base Socket Plate - Bosch SPS40C12GB Repair Instructions

Hide thumbs Also See for SPS40C12GB:
Table of Contents

Advertisement

Repairs
6.35

Replacing the base socket plate

The base socket plate is situated in the lower area at the front.
Prerequisite:
Appliance is disconnected from the power supply.
Furniture panel has been removed (optional).
Toe panel (optional) has been removed.
6.35.1
Removing the base socket plate
1. Remove two screws (1). Disengage the catch elements (2).
2. Tilt the base socket plate carefully forwards (1).
2016-03-02 / DIS 840_58300000176874_ara_en_c
.
Depending on the model series, the connector to the EmotionLight is
still secured to the base.
► Unlock the plug on the catch tappets and pull to the rear (2 - optional).
6.35.2
Installing the base socket plate
► Mount the base socket plate in reverse order.
Copyright by BSH Hausgeräte GmbH