GE G30 Instruction Manual page 595

Generator protection system 7.4x
Hide thumbs Also See for G30:
Table of Contents

Advertisement

APPENDIX D: MISCELLANEOUS
Page
Description
---
Added Transformer Hottest-Spot temperature, Transformer Aging Factor, Transformer Loss of Life content to description,
specifications, FlexLogic operands table, actual values, FlexAnalog table, Modbus memory map, IMD tables
---
Updated transformer Percent Differential element (for CT Saturation), including 1-out-of-3, including in specifications,
FlexLogic operands, settings, logic diagram, and added actual values
---
Updated Disconnect (Breaker) Switch number from 16 to 8 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Neutral Time Overcurrent (TOC) number from 1 to 2 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Phase Time Overcurrent (TOC) number from 1 to 2 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated number of Phase Instantaneous Overcurrent elements in FlexLogic operands table, settings, features per product
table, Modbus memory map
2-
Updated several specifications, such as TOC, IOC, number of FlexLogic lines
5-38
Added PRT FUNCTION settings in Network section to enable/disable each Ethernet port
5-49
Updated IEC 61850 section
5-177
Updated number of FlexLogic lines from 512 to 1024 in FlexLogic Equation Editor settings section
10-1
Added Monitoring section
10-2
Added Retrieve Files section
C-
Added Command Line Interface appendix
Table D-5: Major changes for G30 manual version AB2 (English)
Page
Description
---
Updated document throughout, including numbers of elements and FlexLogic operands table
---
Added EAC compliance information throughout, including logo on title page, rear panel, added specifications, added life
expectancy and decommissioning, added sections on Repairs, Storage, and Disposal
---
Updated several figures for consistency
2-17
Added UR Signal Processing section
5-
Updated IEC 61850 content
A-
Updated FlexAnalog table
Table D-6: Major changes for G30 manual version AB1 (English)
Page
Description
---
Updated document throughout and put into new template. Major revision.
---
Updated references to digital inputs/outputs to contact inputs/outputs for consistency
---
Added content for advanced IEC 61850, for example in the Settings and Actual Values chapters
2-1
Updated Table 2-1 ANSI device table and single-line diagram
2-
Updated Order Codes and Specifications
5-28
Added RS232 Baud Rate setting to Serial Ports section. Baud rate is now configurable, with two options.
5-32
Added Far-End Fault Indication (FEFI) section
5-182
Added Split Phase Function setting to enable and disable the function
9-2
Added Software Upgrade section to the Maintenance chapter
---
Moved communications appendices B through F to new UR Series Communications Guide for UR 7.3x AB1
C-1
Updated product warranty from 24 months to 10 years
G30 GENERATOR PROTECTION SYSTEM – INSTRUCTION MANUAL
REVISION HISTORY
D
D-3