GE G30 Instruction Manual page 578

Generator protection system 7.4x
Hide thumbs Also See for G30:
Table of Contents

Advertisement

FLEXANALOG ITEMS
Address
FlexAnalog name
10525
SRC 3 Ic Harm[22]
A
10526
SRC 3 Ic Harm[23]
10527
SRC 3 Ic Harm[24]
10528
SRC 3 Ic Harm[25]
10537
SRC 4 Ia THD
10538
SRC 4 Ia Harm[2]
10539
SRC 4 Ia Harm[3]
10540
SRC 4 Ia Harm[4]
10541
SRC 4 Ia Harm[5]
10542
SRC 4 Ia Harm[6]
10543
SRC 4 Ia Harm[7]
10544
SRC 4 Ia Harm[8]
10545
SRC 4 Ia Harm[9]
10546
SRC 4 Ia Harm[10]
10547
SRC 4 Ia Harm[11]
10548
SRC 4 Ia Harm[12]
10549
SRC 4 Ia Harm[13]
10550
SRC 4 Ia Harm[14]
10551
SRC 4 Ia Harm[15]
10552
SRC 4 Ia Harm[16]
10553
SRC 4 Ia Harm[17]
10554
SRC 4 Ia Harm[18]
10555
SRC 4 Ia Harm[19]
10556
SRC 4 Ia Harm[20]
10557
SRC 4 Ia Harm[21]
10558
SRC 4 Ia Harm[22]
10559
SRC 4 Ia Harm[23]
10560
SRC 4 Ia Harm[24]
10561
SRC 4 Ia Harm[25]
10570
SRC 4 Ib THD
10571
SRC 4 Ib Harm[2]
10572
SRC 4 Ib Harm[3]
10573
SRC 4 Ib Harm[4]
10574
SRC 4 Ib Harm[5]
10575
SRC 4 Ib Harm[6]
10576
SRC 4 Ib Harm[7]
10577
SRC 4 Ib Harm[8]
10578
SRC 4 Ib Harm[9]
10579
SRC 4 Ib Harm[10]
10580
SRC 4 Ib Harm[11]
10581
SRC 4 Ib Harm[12]
10582
SRC 4 Ib Harm[13]
10583
SRC 4 Ib Harm[14]
10584
SRC 4 Ib Harm[15]
10585
SRC 4 Ib Harm[16]
10586
SRC 4 Ib Harm[17]
10587
SRC 4 Ib Harm[18]
A-20
Units
Description
%
Source 3 phase C current twenty-second harmonic
%
Source 3 phase C current twenty-third harmonic
%
Source 3 phase C current twenty-fourth harmonic
%
Source 3 phase C current twenty-fifth harmonic
%
Source 4 phase A current total harmonic distortion
%
Source 4 phase A current second harmonic
%
Source 4 phase A current third harmonic
%
Source 4 phase A current fourth harmonic
%
Source 4 phase A current fifth harmonic
%
Source 4 phase A current sixth harmonic
%
Source 4 phase A current seventh harmonic
%
Source 4 phase A current eighth harmonic
%
Source 4 phase A current ninth harmonic
%
Source 4 phase A current tenth harmonic
%
Source 4 phase A current eleventh harmonic
%
Source 4 phase A current twelfth harmonic
%
Source 4 phase A current thirteenth harmonic
%
Source 4 phase A current fourteenth harmonic
%
Source 4 phase A current fifteenth harmonic
%
Source 4 phase A current sixteenth harmonic
%
Source 4 phase A current seventeenth harmonic
%
Source 4 phase A current eighteenth harmonic
%
Source 4 phase A current nineteenth harmonic
%
Source 4 phase A current twentieth harmonic
%
Source 4 phase A current twenty-first harmonic
%
Source 4 phase A current twenty-second harmonic
%
Source 4 phase A current twenty-third harmonic
%
Source 4 phase A current twenty-fourth harmonic
%
Source 4 phase A current twenty-fifth harmonic
%
Source 4 phase B current total harmonic distortion
%
Source 4 phase B current second harmonic
%
Source 4 phase B current third harmonic
%
Source 4 phase B current fourth harmonic
%
Source 4 phase B current fifth harmonic
%
Source 4 phase B current sixth harmonic
%
Source 4 phase B current seventh harmonic
%
Source 4 phase B current eighth harmonic
%
Source 4 phase B current ninth harmonic
%
Source 4 phase B current tenth harmonic
%
Source 4 phase B current eleventh harmonic
%
Source 4 phase B current twelfth harmonic
%
Source 4 phase B current thirteenth harmonic
%
Source 4 phase B current fourteenth harmonic
%
Source 4 phase B current fifteenth harmonic
%
Source 4 phase B current sixteenth harmonic
%
Source 4 phase B current seventeenth harmonic
%
Source 4 phase B current eighteenth harmonic
G30 GENERATOR PROTECTION SYSTEM – INSTRUCTION MANUAL
APPENDIX A: FLEXANALOG OPERANDS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents