Conformance to EC Directives and UL Standards

EC Directives
The EC Directives apply to all such electronic products as those having specific functions and directly
sold to general consumers in EU countries. These products are required to meet the EU unified standards
and to be furnished with CE Marking.
However, our AC servos meet the EC Directives for Low Voltage Equipment so that the machine or
equipment comprising our AC servos can meet relevant EC Directives.
EMC Directives
Our servo systems can meet EMC Directives and related standards. However, to meet these requirements,
the systems must be limited with respect to configuration and other aspects, e.g. the distance between the
servo amplifier and motor is restricted, and some special wiring conditions must be met. This means that
in some cases machines and equipment comprising our servo systems may not satisfy the requirements
for wiring and grounding conditions specified by the EMC Directives. Therefore, conformance to the EMC
Directives (especially the requirements for emission noise and noise terminal voltage) should be examined
based on the final products that include our servo amplifiers and servo motors.
Applicable Standards
Subject
Applicable standard
IEC60034-1
Motor
EN50178
Motor
and
IEC61800-3
amplifier
EN55011
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
EC: International Electrotechnical Commission
EN: Europaischen Normen
EMC: Electromagnetic Compatibility
EMC Requirements for Variable Speed Electric Power Driven Systems
Radio Disturbance Characteristics of Industrial, Scientific and Medical (ISM)
Radio-Frequency Equipment
Electrostatic Discharge Immunity Test
Radio Frequency Electromagnetic Field Immunity Test
Electric High-Speed Transition Phenomenon - Burst Immunity Test
Lightening Surge Immunity Test
High Frequency Conduction - Immunity Test
Instantaneous Outage - Immunity Test
- App. 2 -
Standards referenced by Low-
Vol t age Di r ecti v e
Standards
referenced by
EMC Directives

Advertisement