Accuracy Adjustment
Align the second axis of the Rugby by rotating it 90° so that this axis is
now square to the wall. Allow the unit to self-level completely , then mark
the position of the beam (Position 3)
Rotate the laser 180°, allow it to self-level and mark the opposite side of
the first axis (Position 4).
The Rugby is within its accuracy specification if the four marks are
within ± 3/32" (± 2.6 mm) from the center.