Order Codes - GE N60 Instruction Manual

Network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

CHAPTER 2: PRODUCT DESCRIPTION
Roles
Actual Values
|---------- Front panel labels designer
|---------- Status
|---------- Metering
|---------- Transducer I/O
|---------- Records
|---------- Product Info
Maintenance
|---------- Modbus analyzer
|---------- Change front panel
|---------- Update firmware
|---------- Retrieve file
Table Notes:
RW = read and write access
R = read access
Supervisor = RW (default), Administrator = R (default), Administrator = RW (only if Supervisor role is disabled)
NA = the permission is not enforced by CyberSentry security
CyberSentry server authentication
The UR has been designed to direct automatically the authentication requests based on user names. In this respect, local
account names on the UR are considered as reserved and not used on a RADIUS server.
The UR detects automatically whether an authentication request is to be handled remotely or locally. As there are five local
accounts possible on the UR, if the user ID credential does not match one of the five local accounts, the UR forwards
automatically the request to a RADIUS server when one is provided.
If a RADIUS server is provided, but is unreachable over the network, server authentication requests are denied. In this
situation, use local UR accounts to gain access to the UR system.

2.3 Order codes

The order code is on the product label and indicates the product options applicable.
The N60 is available as a 19-inch rack horizontal mount and consists of the following modules: power supply, CPU, CT/VT,
contact input and output, transducer input and output, and inter-relay communications. Module options are specified at
the time of ordering.
Order codes are subject to change without notice. See the ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
The order code depends on the mounting option (horizontal or vertical) and the type of CT/VT modules (enhanced
diagnostic CT/VT modules or HardFiber
to HardFiber Bricks.
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
Administrator
Engineer
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RW
RW
NA
NA
RW
RW
Yes
No
Yes
No
for the latest options.
TM
process bus modules). The HardFiber process bus module provides an interface
Operator
Supervisor
Observer
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NA
NA
NA
RW
R
R
No
No
No
No
No
No
ORDER CODES
2
2-7

Advertisement

Table of Contents
loading

Table of Contents