2. Choose the alarm number.
Steps:
(1) Move the cursor to ALARM NUM and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3) Click IRIS+ again to confirm and exit edit mode of this column.
Note:
You can configure up to 7 alarms.
3. Configure the alarm input.
Steps:
(1) Move the cursor to ALARM INPUT and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to set the input status. You can configure it as OPEN
(Normally open), CLOSE (Normally closed) or OFF (disable the alarm input).
(3) Click IRIS+ again to confirm.
Note:
If you set the status as OPEN, alarm will be triggered by high electricity level; if you set the
status as CLOSE, alarm will be triggered by low electricity level; if you set the status as OFF, it
will be triggered when this input channel is shut off.
4. Configure the alarm linkage action.
You can specify the linked action when an alarm occurs. On the ALARM ACT submenu, you can
set the alarm action as preset 1-8, pattern 1-4, patrol 1-8, panning scan, tilting scan, random
scan, frame scan, panoramic scan, day mode, night mode or none. You can also set the alarm
output for the alarm. Please refer to Section 3.5.3 Configuring Auxiliary Alarm Output for
details.
5. Configure alarm priority.
Enter the PRIORITY menu and set the alarm priority as HIGH, MID or LOW.
If multiple alarms with different priorities are triggered at the same time, the speed dome only
responds to the alarm with the highest priority; if multiple alarms with the same priority are
triggered at the same time, then the speed dome will respond to each alarm according to the
defined alarm sequence.

3.5.2 Configuring Alarm Parameters

Purpose:
© Hikvision Digital Technology C o., Ltd. All Rights Reserved.
ALARM
ALARM RESUME
ON
ALARM SEQUENCE
5
ALARM REST DELAY
5
ALARM SETTING
BACK
EXIT
Alarm Configuration Menu
Figure 3-25
ALARM SETTING
ALARM NUM
1
PRIORITY
HIGH
ALARM ACT
NONE
AUX
NONE
ALARM INPUT
OPEN
BACK
EXIT