Configuring Alarm Parameters - HIKVISION DS-2AE7230T User Manual

Hd-tvi speed dome
Table of Contents

Advertisement

User Manual of HD-TVI Speed Dome
(1) Move the cursor to ALARM NO. and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3) Click IRIS+ again to confirm and exit edit mode of this column.
You can configure up to 2 alarm inputs.
3. Move the cursor to ALARM SETTING and click the IRIS+ to enter the setting alarm submenu.
4. Configure the alarm input.
Steps:
(1) Move the cursor to ALARM INPUT and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to set the input status. You can configure it as OPEN
(Normally open), CLOSE (Normally closed) or OFF (disable the alarm input).
(3) Click IRIS+ again to confirm.
If you set the status as OPEN, alarm will be triggered by high electricity level; if you set
the status as CLOSE, alarm will be triggered by low electricity level; if you set the status as OFF,
it will be triggered when this input channel is shut off.
5. Configure the alarm linkage action.
You can specify the linked action when an alarm occurs.
(1) Move the cursor to LINKAGE and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to choose the desired linkage action. You can set
the alarm action as preset from 1 to 8, pattern from 1 to 5, patrol from 1 to 10, panning
scan, tilting scan, panoramic scan, day mode, night mode or none. You can also set the
alarm output for the alarm. Please refer to Section 3.5.3 Configuring Alarm Output for
details.
6. Configure alarm priority.
Enter the PRIORITY menu and set the alarm priority as HIGH, MIDUEM or LOW.
If multiple alarms with different priorities are triggered at the same time, the dome only
responds to the alarm with the highest priority. If multiple alarms with the same priority are
triggered at the same time, then the dome will respond to each alarm according to the defined
alarm sequence.

3.5.2 Configuring Alarm Parameters

Purpose:
You can set the alarm related parameters following below instructions, including linkage action
interval, alarm duration and dome activity resumption.
Steps:
1. Enter the alarm parameter configuration menu:
MAIN MENUS > DOME SETTINGS > ALARM INPUT
2. Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the speed dome will
respond to one alarm first and then respond to the next one after the user-defined interval. You
can set the on SEQUENCE submenu from 1 to 200 seconds.
© Hikvision
Lo-Call 1890 866 900
www.cctvireland.ie
31