(1) Move the cursor to ALARM NO. and click the IRIS+ to enter the editing mode.
(2) Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3) Click IRIS+ again to confirm and exit editing mode of this column.
3. Move the cursor to ALARM SETTING and click the IRIS+ to enter the setting alarm submenu.
4. Configure the alarm input.
Steps:
(1) Move the cursor to ALARM INPUT and click the IRIS+ to enter the editing mode.
(2) Click the up and down direction buttons to set the input status. You can configure it as OPEN
(Normally open), CLOSE (Normally closed) or OFF (disable the alarm input).
(3) Click IRIS+ again to confirm.
If you set the status to OPEN, alarm will be triggered by high electricity level; if you set the
status to CLOSE, alarm will be triggered by low electricity level; if you set the status to OFF, it
will be triggered when this input channel is shut off.
5. Configure the alarm linkage action.
You can specify the linked action when an alarm occurs.
(1) Move the cursor to ALARM AC and click the IRIS+ to enter the editing mode.
(2) Click the up and down direction buttons to choose the desired linkage action. You can also
set the alarm output for the alarm. Refer to Section 3.5.3 Configuring Auxiliary Alarm
Output for details.
6. Configure alarm priority.
Enter the PRIORITY menu and set the alarm priority to HIGH, MIDUEM or LOW.
If multiple alarms with different priorities are triggered at the same time, the dome only
responds to the alarm with the highest priority. If multiple alarms with the same priority are
triggered at the same time, then the dome will respond to each alarm according to the defined
alarm sequence.

3.5.2 Configuring Alarm Parameters

Purpose:
You can set the alarm related parameters by following instructions below, including linkage action
interval, alarm duration, and dome activity resumption.
Steps:
1. Enter the alarm parameter configuration menu:
MAIN MENUS > SYS SETTINGS > ALARMS
2. Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the speed dome will
respond to one alarm first and then respond to the next one after the user-defined interval.
3. Configure the alarm rest delay.
If a linkage action has already been triggered by an alarm input, the speed dome will only
respond to the input from the same channel again after the user-defined reset delay time. This
is the rest time that the speed dome considers an alarm to be active when it is physically