14
. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
TORQUE VALUES
Pulser coil bolt
Coil lock bolt
Flywheel nut
Cooling fan bolt
SPECIAL TOOLS
Universal holder
Flywheel puller
TESTING INSTRUMENTS
Kowa electric tester
Sanwa electric tester
TROUBLESHOOTING
No power
• Dead battery
• Disconnected battery cable
• Fuse burned out
• Faulty ignition switch
Low power
• Weak battery
• Loose battery connection
• Charging system failure
• Faulty regulator/rectifier
Charging indicator light does not come on
• Dead battery
• Faulty charging indicator
• Faulty indicator light bulb
Charging indicator light does not go out
• Faulty battery
• Faulty charging indicator
• Faulty regulator/rectifier
0.5kg-m
0.9kg-m
5.5kg-m
0.9kg-m
Intermittent power
• Loose battery cable connection
• Loose charging system connection
• Loose connection or short circuit in
lighting system
Charging system failure
• Loose, broken or shorted wire or connector
• Faulty regulator/rectifier
• Faulty A.C. generator
14-2