5. Type Tests

5.2. IEEE 1613 Type Tests

IEEE Test
C37.90.3
C37.90.2
C37.90.1
C37.90.1
C37.90
C37.90
Table 5.2. IEEE 1613 Type Tests
Meets Class 2 requirements for an all fiber configuration; meets Class 1 for copper
ports.

5.3. IEC Environmental Type Tests

Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Table 5.3. Environmental Type Tests
RuggedCom® RuggedSwitch™
IEEE 1613 Clause
9
8
Radiated RFI
7
Fast Transient
7
Oscillatory
6
H.V. Impulse
6
Dielectric Strength
Description
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
Description
Enclosure Contact
ESD
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
A.C. Power ports
Earth ground ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Test Ad
Test Bd
Test Db
25
Test Levels
+/- 2kV, +/- 4kV, +/- 8kV
+/- 4kV, +/- 8kV, +/- 15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
2.5kV common mode @ 1MHz
2.5kV common, 1kV diff. mode @ 1MHz
2.5kV common, 1kV diff. mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2kV AC
2kV AC
2kV AC
Test Levels
-40 deg. C, 16 Hours
+85 deg. C, 16 Hours
95% (non-condensing), 55°C, 6 cycles
2g @ (10-150) Hz
30g @ 11 ms
RS950G Installation Guide Rev 100