Ieee 1613 (C37.90.X) Emi Immunity Type Tests; Environmental Type Tests - RuggedCom RuggedBackbone RX1512 Hardware Installation Manual

Rugged layer 3 switch and router
Hide thumbs Also See for RuggedBackbone RX1512:
Table of Contents

Advertisement

5. EMI And Environmental Type Tests
Test
IEEE C37.90.3
IEEE C37.90.2
IEEE C37.90.1
IEEE C37.90.1
IEEE C37.90
IEEE C37.90
a
Meets Class 2 requirements for an all-fiber configuration. Meets Class 1 requirements for copper ports.
Table 5.2. IEEE 1613 (C37.90.x) EMI Immunity Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Table 5.3. Environmental Type Tests
RuggedCom® RuggedBackbone™
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
H.V. Impulse
Dielectric Strength
Description
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
Earth ground ports
Signal ports
D.C. Power ports
2.5kV common, 1kV diff. mode@1MHz
Signal ports
D.C. Power ports
Signal ports
D.C. Power ports
a
Test Ad
Test Bd
Test Db
95% (non-condensing), 55°C , 6 cycles
41
RX1512 Installation Guide Rev 105
Test Levels
+/-2kV, +/-4kV, +/- 8kV
+/-4kV, +/-8kV, +/-15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
2.5kV common mode @1MHz
5kV (Fail-Safe Relay output)
5kV
2kVAC
2kVDC
Test Levels
-40°C, 16 Hours
+85°C, 16 Hours
2g @ (10 - 150) Hz
30g @ 11mS