Siemens 6SE7022-1EP60 Operating Instructions Manual
Siemens 6SE7022-1EP60 Operating Instructions Manual

Siemens 6SE7022-1EP60 Operating Instructions Manual

Simovert masterdrives vector control series frequency converter (ac-ac) compact plus type
Table of Contents

Advertisement

Aotewell Ltd
SIMOVERT MASTERDRIVES
Vector Control
Frequenzumrichter (AC-AC) Bauform Kompakt PLUS
Frequency Converter (AC-AC) Compact PLUS Type
Ausgabe / Edition: AB
HongKong|UK|China
www.aotewell.com
sales@aotewell.com
Industry Automation
Betriebsanleitung
Operating Instructions
Bestell-Nr. / Order No.: 6SE7087-6JP60
+86-755-8660-6182

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6SE7022-1EP60 and is the answer not in the manual?

Questions and answers

Summarization of Contents

SIMOVERT MASTERDRIVES
Vector Control
Specifies the control method for the SIMOVERT MASTERDRIVES.
Frequenzumrichter (AC-AC) Bauform Kompakt PLUS
Identifies the AC-AC frequency converter type and form factor.
Frequency Converter (AC-AC) Compact PLUS Type
English title for the AC-AC Compact PLUS frequency converter.
1 Definitions and Warnings
Qualified Personnel
Defines the necessary qualifications for handling the equipment safely.
Safety Alert Symbols
Explains the meaning of DANGER, WARNING, CAUTION, and NOTICE symbols.
General Safety Instructions
Outlines crucial safety guidelines for equipment operation.
2 Description
Range of Application
Describes the typical uses and capabilities of the frequency converter.
Circuit Principle
Illustrates the internal functional blocks and data flow of the converter.
3 First Start-up
Initial Unit Checks
Procedures for unpacking and verifying the unit's condition.
Power Cable Connection
Instructions for connecting main power and auxiliary supplies.
Critical Disconnection Warning
Emphasizes disconnecting power before connecting control circuits.
4 Transport, Storage, Unpacking
Transport Precautions
Outlines measures to prevent damage during transportation.
Storage Conditions
Specifies environmental conditions for storing the equipment.
Unpacking Procedure
Details the steps for safely removing the unit from its packaging.
5 Installation
5.1 Installing the Units
Step-by-step guide for unit mounting and placement.
Installation Requirements
Specifies environmental and location prerequisites for installation.
Mounting Clearances
Details the necessary space around the unit for proper cooling.
6 Installation in Conformance with EMC Regulations
General EMC Installation Guidelines
General recommendations for meeting EMC standards.
Cable Shielding and Grounding
Instructions on proper shielding and grounding of cables for EMC.
Noise Suppression Filters
Information on using filters to reduce electromagnetic interference.
7 Connecting-up
Connection Safety and Notices
Highlights critical safety warnings and important notices for wiring.
Power Terminals and Control Terminals
Identifies key power and control terminals for connection.
Residual Current Device (RCD) Requirements
Specifies requirements for residual-current protective devices.
7 Connecting-up
7.1 Power Connections
Detailed guide for connecting the main power supply to the unit.
X1 Mains Connection
Specifics on connecting the main AC power input terminals.
X3 DC Link Bus Module
Details for connecting the DC link bus module for power distribution.
X2 Motor Connection
Instructions for connecting the motor output terminals.
8 Parameterization
Parameter Menus Overview
Explains the hierarchical structure of unit parameters.
Parameter Access Control
Describes how to manage access levels for parameter settings.
P60 Menu Selection
Details how to select main parameter menus using parameter P60.
9 Parameterizing Steps
Detailed Parameterization
Describes the process for in-depth parameter adjustment.
Quick Parameterization
Explains methods for rapid parameter setup.
Power Section Definition
Steps for defining the unit's power section configuration.
9 Parameterizing Steps
9.1 Parameter Reset to Factory Setting
Procedure to restore unit parameters to their default factory state.
Select Fixed Settings Menu
Steps to navigate to the fixed settings menu for reset.
Grant Parameter Access
How to enable parameter modification before reset.
Parameter Reset Sequence
Illustrates the sequence of operations for a factory reset.
10 Maintenance
DANGER: High Voltage Warning
Critical safety warning regarding hazardous voltages during maintenance.
10.1 Replacing the Fan
Guide for replacing the cooling fan unit.
Fan Service Life
Information on the expected lifespan of the fan unit.
11 Forming
CAUTION: DC Link Capacitor Warning
Warning about potential unit damage if capacitors are not reformed.
Serial Number Interpretation
Explains how to determine the unit's manufacture date from its serial number.
Forming Procedure
Step-by-step instructions for reforming the DC link capacitors.
12 Technical Data
Compliance Standards
Lists relevant EC directives and EN standards the unit complies with.
Environmental Conditions
Specifies operating and storage environmental parameters.
Dimensions and Weights
Provides physical characteristics and weight of the unit.
13 Faults and Alarms
General Fault Information
Explains how fault messages are displayed and managed.
F001 Main Contactor Checkback Fault
Details cause and counter-measure for main contactor checkback faults.
F006 DC Link Overvoltage Fault
Explains DC link overvoltage faults and their resolution.
13 Faults and Alarms
F008 DC Link Undervoltage Fault
Addresses faults related to low DC link voltage conditions.
F010 DC Link Overvoltage Fault
Discusses issues arising from excessive DC link voltage.
F012 I Too Low Fault
Identifies causes and solutions for low current conditions.
F015 Motor Stall Fault
Identifies causes and solutions for motor stalling or locking.
13 Faults and Alarms
Alarms Overview
Introduces the alarm system and how alarms are displayed.
A001 Calculating Time Alarm
Details alarms related to high CUVC board calculation time.
A015 External Alarm 1
Addresses alarms triggered by external alarm input 1.
A020 Overcurrent Alarm
Explains alarms related to overcurrent conditions.
14 Environmental Friendliness
Plastics Component Usage
Lists the types of plastics used in the unit's construction.
Production Environmental Aspects
Discusses environmental considerations during the manufacturing process.
Disposal Environmental Aspects
Provides guidance on the environmentally responsible disposal of the unit.

Table of Contents