Encapsulated Remote Port Monitoring; Changes To Default Behaviorconfiguration Steps For Erpm - Dell S4048–ON Configuration Manual

S-series 10gbe switches
Hide thumbs Also See for S4048–ON:
Table of Contents

Advertisement

4.
Create Source RPM session as follows (port-channel 1 and port-channel 2 are LACP).
Dell(conf)#monitor session 1 type rpm
Dell(conf-mon-sess-1)#source port-channel 1 destination remote-vlan 10 dir rx
Dell(conf-mon-sess-1)#no disable
5.
Show the output for the LACP.
Dell#show interfaces port-channel brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
LAG
Mode
L1
L3
L2
L2
Dell#

Encapsulated Remote Port Monitoring

Encapsulated Remote Port Monitoring (ERPM) copies traffic from source ports/port-channels or source VLANs and forwards the
traffic using routable GRE-encapsulated packets to the destination IP address specified in the session.
Important:
When configuring ERPM, follow these guidelines
The Dell Networking OS supports ERPM source session only. Encapsulated packets terminate at the destination IP address
or at the analyzer.
You can configure up to four ERPM source sessions on switch.
The system MTU should be configured properly to accommodate the increased size of the ERPM mirrored packet.
The maximum number of source ports that can be defined in a session is 128.
The system encapsulates the complete ingress or egress data under GRE header, IP header and outer MAC header and
sends it out at the next hop interface as pointed by the routing table.
The keyword 'flow-based enable' should have been specified in case of source as vlan or where monitoring on a per flow
basis is desired.
The keyword monitor should have been specified in the access list rules for which we need to mirror.
The maximum number of source ports that can be defined in a session is 128.
The system allows to configure upto 4 ERPM sessions.
ERPM sessions do not copy locally sourced remote VLAN traffic from source trunk ports that carry RPM VLANs. ERPM
sessions do not copy locally sourced ERPM GRE-encapsulated traffic from source ports.
Source Vlan monitoring can be done only for ingress packets and is not supported for egress direction.
A flow-based source VLAN can be monitored only for ingress traffic (not egress traffic). direction.
Changes to Default Behavior
Rate-limiting ïs no longer done for ERSPAN traffic.
Same port can be configured as both source and destination in an ERSPAN session.
TTL and ToS values can be configured in IP header of ERSPAN traffic.
Configuration steps for ERPM
To configure an ERPM session:
Table 66. Configuration steps for ERPM
Step
Command
1
configure terminal
Status
Uptime
up
00:01:17
up
00:00:58
Ports
Te 1/4
(Up)
Te 1/5
(Up)
Purpose
Enter global configuration mode.
655
Port Monitoring

Advertisement

Table of Contents
loading