5
Member
not present
6
Member
not present
7
Member
not present
8
Member
not present
9
Member
not present
10
Member
not present
11
Member
not present
The following example shows the show system stack-ports command.
Dell#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin
------------------------------------------------------------------
1/56
3/56
1/60
3/60
3/48
3/52
3/56
0/56
3/60
0/60

Influencing Management Unit Selection on a Stack

Stack priority is the system variable that Dell Networking OS uses to determine which units in the stack are the master and standby
management units. If multiple units tie for highest priority, the unit with the highest MAC address prevails.
If management was determined by priority only, a change in management occurs when:
the management unit is powered down or a failover occurs.
you disconnect the management unit from the stack.
When the management unit fails, the unit disappears from the stack topology. At that time, the standby unit detects the
communication loss and switches from the standby unit role to the management unit role in the stack. From the remaining units in
the stack, the system selects a new standby unit based on the unit priority using the same algorithm used when the stack was
initially created. When the failed unit recovers, it takes the next available role, usually that of a stack member.
Influence the selection of the stack management units.
CONFIGURATION mode
stack-unit priority
The unit with the numerically highest priority is elected the master management unit, and the unit with the second highest
priority is the standby unit.
The range is from 1 to 14.
The default is 0.

Managing Redundancy on a Stack

Use the following commands to manage the redundancy on a stack.
Reset the current management unit and make the standby unit the new master unit.
EXEC Privilege mode
redundancy force-failover stack-unit
A new standby is elected. When the former stack master comes back online, it becomes a member unit.
Prevent the stack master from rebooting after a failover.
CONFIGURATION mode
redundancy disable-auto-reboot stack-unit
836
Stacking
Link
(Gb/s)
Status Status Group
40
up
up
40
up
up
40
up
down
40
up
down
40
up
up
40
up
up
Trunk

Advertisement

Table of Contents
loading