3.13 Rf Receiver Configuration; 3.14 Linking Function - Riello BeSMART Installer And User Manual

Wifi box and boiler rf receiver
Hide thumbs Also See for BeSMART:
Table of Contents

Advertisement

3.13 RF receiver configuration

The RF receiver must be configured
for use as a boiler RF receiver or RF
receiver for the zone valve.
To configure the RF receiver pro-
ceed as follows:
− Power up the receiver
− Press button B once during the
two seconds in which the green
and red leds remain lit.
The operating mode of the RF recei-
ver switches from boiler RF receiver
to zone valve RF receiver and vice
versa.
Boiler RF
receiver
The change in configuration is
identifiable by the different flashing
mode of the green led.
Configured as boiler RF receiver
Green LED Red LED
0.5 sec. on
Relay Off
0.5 sec. off
0.2 sec. on
Relay On
0.2 sec. off
Relay Off
Relay On
NOTE
If the receiver is configured as a
boiler RF receiver, the Opentherm
connection to the boiler should be
detached to enable display of the
flashing green led.

3.14 Linking function

BeSMART linking with the WiFi
Box
The BeSMART and the WiFi Box in
the WiFi BeSMART package are al-
ready linked.If installing an addition-
al BeSMART, follow the procedure
below.Ensure that the BeSMART
and the WiFi Box are connected to
a power source and there are no
alarms.Press the prismatic dome
B
clear LED button (A) and hold for
5 seconds until the green and red
LEDs slow flashing (1 seconds) at
the same time (once linked the flash
will return to normal).
-
-
72
Configured as zone receiver
Green LED Red LED
2 sec. on
2 sec. off
1 sec. on
1 sec. off
WiFi Box
-
-
A

Hide quick links:

Advertisement

Table of Contents
loading