Parameter
tSEt
ESC
MODE
tFLO
ESC
MODE
trEt
ESC
MODE
tdH
ESC
MODE
Description
Heating delivery setpoint calculated by the
BeSMART (shown only if the BeSMART
has received a heating request). The val-
ue calculated by the BeSMART may differ
from the real heating delivery setpoint de-
livered by the boiler, if the minimum boiler
heating setpoint parameter is higher than
this value.
EXAMPLE:
The heating delivery setpoint calculated by
the BeSMART is 30°C, the minimum boiler
heating setpoint parameter is 40°C, the real
heating delivery setpoint delivered by the
boiler is 40°C.
Temperature read by the boiler heating
delivery probe (available with OTBus con-
nection between the WiFi Box and the boil-
er or the RF receiver and the boiler or the
BeSMART and the boiler, if provided for by
the OTBus protocol).
Temperature read by the boiler heating re-
turn probe (available with OTBus connec-
tion between the WiFi Box and the boiler
or the RF receiver and the boiler or the
BeSMART and the boiler, if provided for by
the OTBus protocol).
Temperature read by the boiler DHW probe
(available with OTBus connection between
the WiFi Box and the boiler or the RF receiv-
er and the boiler or the BeSMART and the
boiler, if provided for by the OTBus protocol).