Parameter
19 HOFF
ESC
MODE
21 ALL
ESC
MODE
22 tSP
ESC
MODE
Description
Setting the OFF hysteresis for heating or
cooling requests.
The value can be set from 0°C to 2°C; the
default setting is 0.1°C.
The BeSMART processes an OFF request
above the target room temperature set (de -
sired room setpoint + H OFF) if the heating
mode is active, or below the target room tem -
perature set (desired room setpoint – H OFF)
if the cooling mode is active.
Alarm history display (available with OTBus
connection between the WiFi Box and the
boiler or the RF receiver and the boiler or
the BeSMART and the boiler, if provided for
by the OTBus protocol). The last 9 alarms
generated by the boiler and saved by the
BeSMART are shown.
Setting boiler parameters (available with OT -
Bus connection between the WiFi Box and
the boiler or the RF receiver and the boiler
or the BeSMART and the boiler, if provided
for by the OTBus protocol). This parameter
is set by the Authorised Service Centre.