B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 68 of 72)
ADDR
REGISTER NAME
D3A0
...Repeated for Remote Device 9
D3A4
...Repeated for Remote Device 10
D3A8
...Repeated for Remote Device 11
D3AC
...Repeated for Remote Device 12
D3B0
...Repeated for Remote Device 13
D3B4
...Repeated for Remote Device 14
D3B8
...Repeated for Remote Device 15
D3BC
...Repeated for Remote Device 16
D3C0
...Repeated for Remote Device 17
D3C4
...Repeated for Remote Device 18
B
D3C8
...Repeated for Remote Device 19
D3CC
...Repeated for Remote Device 20
D3D0
...Repeated for Remote Device 21
D3D4
...Repeated for Remote Device 22
D3D8
...Repeated for Remote Device 23
D3DC
...Repeated for Remote Device 24
D3E0
...Repeated for Remote Device 25
D3E4
...Repeated for Remote Device 26
D3E8
...Repeated for Remote Device 27
D3EC
...Repeated for Remote Device 28
D3F0
...Repeated for Remote Device 29
D3F4
...Repeated for Remote Device 30
D3F8
...Repeated for Remote Device 31
D3FC
...Repeated for Remote Device 32
Phasor Measurement Unit Basic Configuration (Read/Write Setting) (4 modules)
D400
PMU x Function
D401
PMU x LDInst
D422
PMU x IDcode
D423
PMU x STN
D42B
PMU x Source
D42C
PMU x Class
D42D
PMU x Format
D42E
PMU x Style
D42F
PMU x Rate
D430
PMU x PHS-x (14 items)
D43E
PMU x PHS-x Name (14 items)
D4AE
PMU x A-CH-x (16 items)
D4BE
PMU x A-CH-x (16 items)
D53E
PMU x D-CH-x (16 items)
D55E
PMU x D-CH-x Name (16 items)
D5DE
PMU x D-CH-x Normal State (16 items)
D5EE
PMU x Reserved (16 items)
Contact Outputs (Read/Write Setting) (64 modules)
DC90
Contact Output 1 Name
DC96
Contact Output 1 Operation
DC98
Contact Output 1 Seal In
DC9A
Latching Output 1 Reset
DC9C
Contact Output 1 Events
DC9D
Latching Output 1 Type
DC9E
Reserved
DC9F
...Repeated for Contact Output 2
DCAE
...Repeated for Contact Output 3
B-76
RANGE
0 to 1
---
1 to 65534
---
0 to 5
0 to 2
0 to 1
0 to 1
0 to 13
0 to 14
---
0 to 65535
---
0 to 4294967295
---
0 to 1
0 to 1
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
---
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F214
---
1
F001
---
---
F203
"GE-UR-PMU"
---
1
F167
---
1
F549
---
1
F547
---
1
F546
---
1
F544
---
1
F543
---
---
F203
"GE-UR-PMU-
---
1
F600
---
---
F203
"AnalogChannel 1
---
1
F300
---
---
F203
"Dig Channel 1 "
---
1
F108
---
1
F001
---
---
F205
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F090
---
---
F001
DEFAULT
0 (Disabled)
"PMUx \040"
1
0 (SRC 1)
1 (Class M)
0 (Integer)
0 (Polar)
4 (10/sec)
1 (Va)
PHS 1 "
0
"
0
0 (Off)
0
"Cont Op 1"
0
0
0
1 (Enabled)
0 (Operate-
dominant)
0
GE Multilin