GE D60 Instruction Manual page 592

Line distance protection system, ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 8 of 11)
A
ADDRESS
FLEXANALOG NAME
9538
PMU 1 Va Angle
9539
PMU 1 Vb Mag
9541
PMU 1 Vb Angle
9542
PMU 1 Vc Mag
9544
PMU 1 Vc Angle
9545
PMU 1 Vx Mag
9547
PMU 1 Vx Angle
9548
PMU 1 V1 Mag
9550
PMU 1 V1 Angle
9551
PMU 1 V2 Mag
9553
PMU 1 V2 Angle
9554
PMU 1 V0 Mag
9556
PMU 1 V0 Angle
9557
PMU 1 Ia Mag
9559
PMU 1 Ia Angle
9560
PMU 1 Ib Mag
9562
PMU 1 Ib Angle
9563
PMU 1 Ic Mag
9565
PMU 1 Ic Angle
9566
PMU 1 Ig Mag
9568
PMU 1 Ig Angle
9569
PMU 1 I1 Mag
9571
PMU 1 I1 Angle
9572
PMU 1 I2 Mag
9574
PMU 1 I2 Angle
9575
PMU 1 I0 Mag
9577
PMU 1 I0 Angle
9578
PMU 1 Freq
9580
PMU 1 df dt
9581
PMU 1 Conf Ch
12306
Oscill Num Triggers
13504
DCMA Inputs 1 Value
13506
DCMA Inputs 2 Value
13508
DCMA Inputs 3 Value
13510
DCMA Inputs 4 Value
13512
DCMA Inputs 5 Value
13514
DCMA Inputs 6 Value
13516
DCMA Inputs 7 Value
13518
DCMA Inputs 8 Value
13520
DCMA Inputs 9 Value
13522
DCMA Inputs 10 Value
13524
DCMA Inputs 11 Value
13526
DCMA Inputs 12 Value
13528
DCMA Inputs 13 Value
13530
DCMA Inputs 14 Value
13532
DCMA Inputs 15 Value
13534
DCMA Inputs 16 Value
A-8
UNITS
DESCRIPTION
Degrees
Phasor measurement unit 1 phase A voltage angle
Volts
Phasor measurement unit 1 phase B voltage magnitude
Degrees
Phasor measurement unit 1 phase B voltage angle
Volts
Phasor measurement unit 1 phase C voltage magnitude
Degrees
Phasor measurement unit 1 phase C voltage angle
Volts
Phasor measurement unit 1 auxiliary voltage magnitude
Degrees
Phasor measurement unit 1 auxiliary voltage angle
Volts
Phasor measurement unit 1 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 1 positive-sequence voltage angle
Volts
Phasor measurement unit 1 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 1 negative-sequence voltage angle
Volts
Phasor measurement unit 1 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 1 zero-sequence voltage angle
Amps
Phasor measurement unit 1 phase A current magnitude
Degrees
Phasor measurement unit 1 phase A current angle
Amps
Phasor measurement unit 1 phase B current magnitude
Degrees
Phasor measurement unit 1 phase B current angle
Amps
Phasor measurement unit 1 phase C current magnitude
Degrees
Phasor measurement unit 1 phase C current angle
Amps
Phasor measurement unit 1 ground current magnitude
Degrees
Phasor measurement unit 1 ground current angle
Amps
Phasor measurement unit 1 positive-sequence current magnitude
Degrees
Phasor measurement unit 1 positive-sequence current angle
Amps
Phasor measurement unit 1 negative-sequence current magnitude
Degrees
Phasor measurement unit 1 negative-sequence current angle
Amps
Phasor measurement unit 1 zero-sequence current magnitude
Degrees
Phasor measurement unit 1 zero-sequence current angle
Hz
Phasor measurement unit 1 frequency
Hz/s
Phasor measurement unit 1 rate of change of frequency
---
Phasor measurement unit 1 configuration change counter
---
Oscillography number of triggers
mA
dcmA input 1 actual value
mA
dcmA input 2 actual value
mA
dcmA input 3 actual value
mA
dcmA input 4 actual value
mA
dcmA input 5 actual value
mA
dcmA input 6 actual value
mA
dcmA input 7 actual value
mA
dcmA input 8 actual value
mA
dcmA input 9 actual value
mA
dcmA input 10 actual value
mA
dcmA input 11 actual value
mA
dcmA input 12 actual value
mA
dcmA input 13 actual value
mA
dcmA input 14 actual value
mA
dcmA input 15 actual value
mA
dcmA input 16 actual value
D60 Line Distance Protection System