Direct Inputs - GE D60 Instruction Manual

Line distance protection system, ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

6 ACTUAL VALUES
Accuracy is the estimated maximum time error at present in the RTC, considering the quality information imbedded in the
received time signal. The value 999,999,999 indicates that the magnitude of the estimated error is one second or more, or
that the error cannot be estimated.
is the present state of the port's PTP clock. The PTP clock state is:
PORT 1...3 PTP STATE
is the port's function setting is Disabled,
DISABLED
if enabled but no signal from an active master has been found and selected,
NO SIGNAL
if an active master has been selected but lock is not at present established,
CALIBRATING
if the port is synchronized, but the peer delay mechanism is non-operational, and
SYNCH'D (NO PDELAY)
if synchronized.
SYNCHRONIZED
is the time difference, measured in nanoseconds, between the fractional seconds portion of the time
PTP-— IRIG-B DELTA
being received via PTP and that being received via IRIG-B. A positive value indicates that PTP time is fast compared to
IRIG-B time.
PATH: ACTUAL VALUES
STATUS
 DIRECT INPUTS
MESSAGE
MESSAGE
MESSAGE
MESSAGE
MESSAGE
MESSAGE
MESSAGE
MESSAGE
The
AVERAGE MSG RETURN TIME
ring configuration (this value is not applicable for non-ring configurations). This is a rolling average calculated for the last
ten messages. There are two return times for dual-channel communications modules.
The
UNRETURNED MSG COUNT
make the trip around the communications ring. The
direct output messages that have been received but fail the CRC check. High values for either of these counts may indicate
on a problem with wiring, the communication channel, or one or more relays. The
values can be cleared using the
COUNT
The
to
DIRECT INPUT 1
DIRECT INPUT (32)
GE Multilin


DIRECT INPUTS

AVG MSG RETURN
TIME CH1: 0 ms
UNRETURNED MSG
COUNT CH1: 0
CRC FAIL COUNT
CH1: 0
AVG MSG RETURN
TIME CH2: 0 ms
UNRETURNED MSG
COUNT CH2: 0
CRC FAIL COUNT
CH2: 0
DIRECT INPUT
1:
On
DIRECT INPUT
2:
On
DIRECT INPUT 32:
On
is the time taken for direct output messages to return to the sender in a direct input/output
values (one per communications channel) count the direct output messages that do not
CRC FAIL COUNT
CLEAR DIRECT I/O COUNTERS
values represent the state of each direct input.
D60 Line Distance Protection System
values (one per communications channel) count the
UNRETURNED MSG COUNT
command.
6.2 STATUS
6.2.15 DIRECT INPUTS
6
and
CRC FAIL
6-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents