GE D60 Instruction Manual page 638

Line distance protection system, ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 34 of 72)
ADDR
REGISTER NAME
689B
Autoreclose Mode 4 Activation
Pilot Directional Comparison Unblocking Scheme (Read/Write Setting)
68A0
Directional Comparison Unblocking Scheme Function
68A1
Directional Comparison Unblocking Block
68A3
Directional Comparison Unblocking Permissive Echo
68A4
Directional Comparison Unblocking Echo Condition
68A6
DCUB Ground Directional Overcurrent Forward
68A8
DCUB Ground Directional Overcurrent Reverse
68AA
DCUB Transmit Block Pickup Delay
68AB
DCUB Transmit Block Reset Delay
B
68AC
Directional Comparison Unblocking Echo Duration
68AD
Directional Comparison Unblocking Echo Lockout
68AE
DCUB Line End Open Pickup Delay
68AF
DCUB Loss-of-Guard Pickup Delay
68B0
DCUB Guard Healthy Reset Delay
68B1
DCUB Loss-of-Guard Trip Window
68B2
Directional Comparison Unblocking Seal-In Delay
68B3
Directional Comparison Unblocking Communication Bits
68B4
Directional Comparison Unblocking Rx1
68B6
Directional Comparison Unblocking LOG1
68B8
Directional Comparison Unblocking Rx2
68BA
Directional Comparison Unblocking LOG2
68BC
Directional Comparison Unblocking Rx3
68BE
Directional Comparison Unblocking LOG3
68C0
Directional Comparison Unblocking Rx4
68C2
Directional Comparison Unblocking LOG4
68C4
Directional Comparison Unblocking Target
68C5
Directional Comparison Unblocking Event
68C6
Reserved (6 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7008
Phase Undervoltage 1 Target
7009
Phase Undervoltage 1 Events
700A
Phase Undervoltage 1 Measurement Mode
700A
Reserved (6 items)
7013
...Repeated for Phase Undervoltage 2
7015
...Repeated for Phase Undervoltage 2
7017
...Repeated for Phase Undervoltage 2
701B
...Repeated for Phase Undervoltage 2
701C
...Repeated for Phase Undervoltage 2
7022
...Repeated for Phase Undervoltage 3
7025
...Repeated for Phase Undervoltage 3
7027
...Repeated for Phase Undervoltage 3
7028
...Repeated for Phase Undervoltage 3
702A
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting)
7040
Phase Overvoltage 1 Function
B-42
RANGE
0 to 4294967295
0 to 1
0 to 4294967295
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F300
---
1
F199
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F198
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
0 (Self-Reset)
--
1
F102
--
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
0 (Definite Time)
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
---
1
F001
---
1
F102
DEFAULT
0
0 (Disabled)
0
0 (Disabled)
0
0
0
20
90
100
250
50
8
15
150
10
0 (1 bit)
0
0
0
0
0
0
0
0
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0 (Phase to
Ground)
0
0 (Disabled)
GE Multilin