Retrieve Operating Mode

Retrieve Operating Mode
This command returns the Operating Mode setting for the system.
Syntax
RTRV-PRMTR-OPERMODE:[tid]::ctag;
Response Format
^^^"mode" <cr lf>
where:
mode = the signal operating mode for the shelf [NORMAL | SUBTENDING]
The NORMAL mode means that the SSU is in normal master mode. In this
mode, the unit selects an input reference from any available input sources.
The SUBTENDING mode means that SSU is in ANSI subtending mode. In this
mode, the unit chooses an available Composite Clock Input as an input
reference. All other inputs shall not be selected as input reference.