Chapter 2 TL1 Reference

Set Clock AutoReturn

Set Clock AutoReturn
The command sets the clock mode of returning or not returning after faults are
cleared. The
| OFF] for revertive or non-revertive operation. See the SSU-2000e User's Guide for
more information on revertive and non-revertive operation.
Syntax
SET-CLK-AR:[tid]::ctag::ar;
Parameter
[ar]
Empty fields leave parameters unchanged.
Related Commands
Retrieve Clock
Retrieve Clock
124 SSU-2000e Technical Reference
parameter changes the active Clock module selection mode to [ON
ar
Value
Sets the active Clock module to the Revertive mode.
ON
Sets the active Clock module to the Non-Revertive mode.
OFF