Retrieve All Alarms - Symmetricom SSU-2000e Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Chapter 2 TL1 Reference

Retrieve All Alarms

Retrieve All Alarms
This command reports all active alarms from the SSU-2000e or designated modules
or ports with an aid indicating which module or port is generating the alarm. The
response is the complied message followed by the alarm report message(s).
There may be no lines or there may be multiple lines in the report, one for each
active alarm. There is no report message for modules or ports that have no alarm
condition.
Syntax
RTRV-ALARM:[tid]:[aid]:ctag;
or
RTRV-ALM:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
"<aid>,aidtype:ntfcncde,condtype,srveff,\"condscr\"<cr><lf>
"<aid>,aidtype:ntfcncde,condtype,srveff,\"condscr\"<cr><lf>
.
.
"<aid>,aidtype:ntfcncde,condtype,srveff,\"condscr\"<cr><lf>
;
where:
= module or port access identifier
aid
ntfcncde
condtype
= service affecting flag (SA, NSA)
srveff
= condition description string
condstr
Related Commands
Retrieve
Events, on page 56
Retrieve Module
Retrieve Alarm
42
SSU-2000e Technical Reference
Value
Retrieves information for all alarms that are currently
ALL
active in the entire shelf.
Retrieves information for all alarms that are currently
SxAy[-z]
active in the specified module [or port].
= notification code (CR, MJ, MN, CL)
= condition type (event number)
Alarms, on page 38
Parameters, on page 40
Description
12713140-003-2 Revision E.01 – January 2007