Chapter 2 TL1 Reference

Retrieve Alarm Cutoff

Retrieve Alarm Cutoff
This command indicates whether the Alarm Cutoff (ACO) function is active in the
SSU-2000e. The command creates a momentary change of state (pulse) on the
alarm relay, which allows a specially-built alarm panel to squelch the audio alarm.
Alarm panels that do not have this capability ignore the pulse. Contact your
Symmetricom representative for further details on this alarm panel.
Syntax
RTRV-ACO:[tid]::ctag;
Response Format
"aco"<cr><lf>
where
is [ACTIVE | INACTIVE]
aco
Related Commands
Set Alarm
Cutoff, on page 118
36
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007