Retrieve Alarm Elevation Time

This command returns the time for alarm elevation, from 60 seconds to 500 000
seconds, for the specified module. A setting of 0 (zero) means the alarm does not
automatically elevate to the next level. When an alarm has been at MINOR or
MAJOR level continuously for
level.
Syntax
RTRV-PRMTR-ELTIME:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
^^^"aid:elevtime" <cr lf>
where:
= module access identifier
aid
elevtime
Related Commands
Set Alarm Level
12713140-003-2 Revision E.01 – January 2007
elevtime
Value
Retrieves the elevtime parameter from the specified
SxAy
module.
= alarm elevation time for the specified module
Parameters, on page 120
Retrieve Alarm Elevation Time
seconds, then it is elevated to the next
Description
SSU-2000e Technical Reference
Chapter 2 TL1 Reference