Chapter 2 TL1 Reference

Set CC Output Parameters

Set CC Output Parameters
This command sets the parameters on the specified Composite Clock Output
module or port.
Syntax
SET-PRMTR-CCOUT:[tid]:[aid]:ctag::[pstate],[mode],[level],[bypass],
[duty],[pcomp];
Parameter
aid
pstate
mode
level
bypass
duty
pcomp
Empty fields leave parameters unchanged.
Related Commands
Retrieve CC Output
122 SSU-2000e Technical Reference
Format
Sets the parameters for the specfied CC Output module
SxAy[-z]
[or port].
Turns the specified module [or port] on or off.
ON | OFF
This parameter is ignored.
Outputs are turned on when the active Clock module is at
ACQ | LOCK
or above the specified state.
Allows operation when Clock C is the active clock.
ON | OFF
Sets the duty cycle on the specified module [or port] to
1 | 0
5/8 (1) or 50/50 (0).
Sets the phase compensation delay on the specified
0 - 7
module [or port], where 0 = No compensation and 8 =
2200 ft. The resolution of pcomp values is 275 ft.