Chapter 2 TL1 Reference

Retrieve CC Output Parameters

Retrieve CC Output Parameters
This command returns the settings for the Composite Clock Output module and port
designated by the aid.
Syntax
RTRV-PRMTR-CCOUT:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
When the aid specifies a port, the format for each response message line is:
^^^"aid:mode,level,bypass,pstate,duty,pcomp"<cr lf>
where:
= port access identifier
aid
= CC (composite clock)
mode
= minimum clock level to enable outputs on the module [WARM | ACQ |
level
LOCK]
= allow Clock C selection: [ON | OFF]
bypass
= port state [ON | OFF]
pstate
= duty cycle of the modules outputs [1 | 0] where 1 = 5/8 and 0 = 50/50
duty
= phase compensation [1 – 7] where 7 = no compensation and 0 = 2200 ft.
pcomp
The resolution is 275 ft.
When the aid specifies a module, then the response is four lines as follows:
^^^"aid: mode,level,bypass"<cr lf>
^^^"aid:pstate1,pstate2,pstate3,...pstate20"<cr lf>
^^^"aid:duty1,duty2,duty3,...duty20"<cr lf>
^^^"aid:pcomp1,pcomp2,pcomp3,...,pcomp20"<cr lf>
Line 1 contains:
= module access identifier
aid
= CC
mode
= minimum clock level to enable outputs on the module [WARM | ACQ |
level
LOCK]
= allow Clock C selection: [ON | OFF]
bypass
44
SSU-2000e Technical Reference
Value
Retrieves the parameters from all CC Output modules in
ALL
the shelf.
Retrieves parameters from the specified CC Output
SxAy[-z]
module [or port].
Description
12713140-003-2 Revision E.01 – January 2007