Retrieve Ds1/E1 Input Parameters - Symmetricom SSU-2000e Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Retrieve DS1/E1 Input Parameters

This command returns the settings for the DS1 or E1 Input module or port
designated by the aid.
Syntax
RTRV-PRMTR-INPUT:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
^^^"aid:pstate,pri,pql,mode,ssm,zs,crc,gain,csflt,bit" <cr lf>
where:
= module or port access identifier
aid
= port enabled state [ON | OFF]
pstate
= priority 1 (highest) through 10 (lowest) or MON for monitor
pri
= provisioned priority quality level [1 – 16]
pql
= framing type or clock frequency in MHz: [ESF | D4 | CCS | CAS | 1 | 1.544
mode
|2.048 | 5 | 10]
,
,
ssm
zs
crc
= Cesium fault [HI | LO | OFF | NA]
csflt
= bit number 4 through 8 of the Time Slot 0 word used for the E1 sync status
bit
message
Related Commands
Set DS1/E1 Input
12713140-003-2 Revision E.01 – January 2007
Value
Retrieves the parameters from all DS1 or E1 Input
ALL
modules in the shelf.
Retrieves parameters from the specified DS1 or E1 Input
SxAy[-z]
module [or port].
, and
= [ON | OFF]
gain
Parameters, on page 128
Chapter 2 TL1 Reference
Retrieve DS1/E1 Input Parameters
Description
SSU-2000e Technical Reference