Consider Housing Rotation - Emerson Rosemount 3051S Quick Start Manual

High static differential pressure transmitter
Hide thumbs Also See for Rosemount 3051S:
Table of Contents

Advertisement

Quick Start Guide
Figure 3. Applying Coaxial Sealant to Cable Connections

3.0 Consider housing rotation

To improve field access to wiring or to better view the optional LCD display:
1. Loosen the housing rotation set screw.
2. First rotate the housing clockwise to the desired location. If the desired
location cannot be achieved due to thread limit, rotate the housing counter
clockwise to the desired location (up to 360° from thread limit).
3. Retighten the housing rotation set screw up to 30 in-lb.
4. For wireless, consider access to the power module when selecting housing
rotation.
Figure 4. Transmitter Housing Set Screw
PlantWeb
A
A. Housing rotation set screw (
Note
Do not rotate the housing more than 180° without first performing a disassembly
procedure. Over-rotation may sever the electrical connection between the sensor module
and the feature board electronics.
8
Junction box
A
3
/
-in.)
32
September 2017

Advertisement

Table of Contents
loading

Table of Contents