Thermo Scientific Orion DUAL STAR
Method Number – Shows the method that is currently being used on that
ready
channel. To change the method number, refer to the Methods section.
25.0
Auto-Read (AR) Read Type Indicator – If Auto-Read was selected as the read
type, the AR icon will appear when the reading is stable and the display has
25.0
ATC2
been locked. To change the read type, refer to the Setup Menu section.
Stabilizing/Ready Read Type Indicator – Specifies the measurement stability of
ATC2
ATC2
the electrode. To change the read type, refer to the Setup Menu section.
ppm
Measurement Mode – Indicates the unit of measurement for the measurement
0.0
value and determines the type of calibration that will be performed. To
0.0
change the measurement mode, refer to the Setup Menu section. If the ISE
measurement mode is changed, the electrode must be re-calibrated with new
0.0
cal
standards that have the same measurement unit as the measurement mode.
15:45
15:45
05/25/2009
Temperature Measurement – Displays the current temperature based on the
05/25/2009
selected ATC probe reading or entered temperature value. To change the
15:45
Ch. setup
temperature display to Celsius or Fahrenheit, refer to the Setup Menu section.
Ch. setup
Temperature Source – Shows the origin of the current temperature
measurement. To change the source of the temperature measurement, refer to
the Setup Menu section.
mV Measurement – Shows the raw millivolt reading of the electrode.
Printer Interface – Indicates if a printer is interfaced with the meter.
ready
7.000
25.0
ready
Computer Interface – Indicates if a computer is interfaced with the meter. The
ATC1
USB icon will only be shown when the meter is connected to a computer via
pH
the USB input.
0.0
Timed Interval Read Type Indicator – Indicates when a timed reading is being
stabilizing
1.00
taken by the meter. To change the read type, refer to the Setup Menu section.
25.0
Autosampler Interface – Indicates if the meter is running the autosampler.
ATC2
ppm
f1 Function – Displays the action that will be done when the f key is pressed.
cal
0.0
f2 Function – Displays the action that will be done when the f key is pressed.
setup
f3 Function – Displays the action that will be done when the f key is pressed.
25.0
ATC2
ppm
0.0
15:45
05/25/2009
Ch. setup
25.0
ATC1
pH
0.0
25.0
ATC2
ppm
0.0
setup
pH/ISE Meter User Guide
Meter Overview