Contents Chapter 1 Meter Introduction ..................6 Meter Overview ..........................6 Packing List ..........................7 Intended Use ..........................7 Chapter 2 Meter Basics ....................8 Using the Universal Power Adapter ..................... 8 Attaching the Electrode Stand ..................... 9 Meter Connections ........................10 Meter Keypad ..........................
Page 4
LogR Temperature Calibration (pH/LogR Module Only) ..........46 Incremental Techniques (pH/ISE Module Only) ................. 48 Single Known Addition ..................... 49 Double Known Addition ....................50 Single Known Subtraction ....................51 Double Known Subtraction ....................52 Single Analate Addition ....................53 Single Analate Subtraction ....................
Page 5
Meter Specifications ........................93 Ordering Information ........................99 Selectable Meter Components ..............99 ERSA Preconfigured Meter Systems ..............99 ERSA Meter Accessories, Electrodes and Solutions ..........101 ERSA Appendix A Channel Specific Settings and Features .......... 104 General Mode Settings ......................104 Sample ID ........................
Meter Introduction C H A P T E R 1 Meter Overview Thermo Scientific Orion meters offer four channels that can be configured in ™ ™ ™ ERSA any combination through their modular design. Measurement modules are automatically recognized by the meter and can be added or removed from channels at any time.
For specific measurement module and kit contents, refer to the Ordering Information section. Visit our website at www.thermoscientific.com/OrionMeters to download the complimentary Thermo Scientific Orion Star Com data transfer computer software and latest V ™ ™ ™...
3. Slide the appropriate plug plate into the groove on the back of the power adapter. 4. Connect the assembled power adapter to a power outlet and the meter input labeled POWER. The use of a surge protector or uninterrupted power supply (UPS) is also recommended. Orion V Meter User Manual Thermo Scientific ERSA...
6. Turn the meter over, with the meter display facing up. 7. Insert the electrode arm into the metal post on the base plate. 8. Connect the electrode holder to the electrode arm using the pivot pin. Thermo Scientific Orion V Meter User Manual...
Chapter 2 Meter Basics Meter Connections 1. Connect a Thermo Scientific Orion Star stirrer probe (Catalog Number 096019) to the ™ ™ ™ STIRRER 1 and/or STIRRER 2 input on the meter. The Orion Star stirrer probes are controlled and powered by the meter, eliminating the need for magnetic stir bars and plates.
Press to enter a decimal point (.) when using the numeric keypad. Press the left arrow (◄) key to scroll left through a list of items. Press to enter a value of four (4) when using the numeric keypad. left arrow (◄) Thermo Scientific Orion V Meter User Manual ERSA...
The following drawing shows the keys that are active when entering a value using the numeric keypad. The decimal (.) key and plus/minus (+/-) key are active so fractional values and positive or negative values can be entered as needed. Orion V Meter User Manual Thermo Scientific ERSA...
3. Unused channels are covered with blank modules. Meter with pH/ISE module, conductivity module, Meter with pH module, pH/LogR module and RDO/DO module and blank module (right to left) blank module (right to left) Thermo Scientific Orion V Meter User Manual ERSA...
2. Pull straight back to remove the module from channel grove on the back of the meter. 3. The meter will automatically recognize that the module has been removed and update the channel ID display (top, left) with dashes in the previous channel location. Orion V Meter User Manual Thermo Scientific ERSA...
– Channels 2 & 3 – Measurement Mode – Temperature with Units and Source – Channels 2 & 4 – Method Number – Electrode ID, Sample ID – Channels 3 & 4 Orion V Meter User Manual Thermo Scientific ERSA...
Page 17
– Main Measurement with Units – Channels 1, 2, 3 & 4 – Channel Number – Secondary Measurement with Units – Measurement Mode – Temperature with Units and Source – Method Number Example Four Channel Display Thermo Scientific Orion V Meter User Manual ERSA...
Date and time Method Channel number pH bulb resistance, appears with LogR temperature compensation Main measurement mode Main measurement units Main measurement value mV corresponding to main measurement Temperature measurement and source Orion V Meter User Manual Thermo Scientific ERSA...
Shown when a meter alarm is triggered. The corresponding alarm identification will also flash on the display as High Limit Alarm, Alarm Icon Limit Alarm, Cal Due Alarm Set Point Alarm. Alarm must be enabled in the channel-specific setup menu. Thermo Scientific Orion V Meter User Manual ERSA...
Electrode condition is bad. The electrode slope is less than 85% or greater than 115%. Consult the pH electrode user manual for instructions on how to clean, condition and troubleshoot the electrode. Orion V Meter User Manual Thermo Scientific ERSA...