IMPORTANT: Replacing the system board battery resets the system ROM to its default
configuration. After replacing the battery, use BIOS/Platform Configuration (RBSU) in the UEFI
System Utilities
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.

Dedicated iLO management module

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power
input modules, and the internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
To remove the component:
Power down the server (on page 27).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 30).
o
Remove the access panel
4.
Remove the primary PCI riser cage
5.
Remove the dedicated iLO management module.
6.
To replace the component, reverse the removal procedure.

Front I/O modules for LFF and SFF drive models

("HPE UEFI System
Utilities" on page 84) to reconfigure the system.
("Access
panel" on page 34).
("Remove the PCI riser
cage" on page 30).
Removal and replacement procedures 65