Dedicated Ilo Management Module; Removing The Dedicated Ilo Management Module - HP ProLiant XL270d Gen9 Maintenance And Service Manual

Accelerator tray
Table of Contents

Advertisement

a. Press and hold both sides of the connector.
b. Disconnect the cable from the server.

Dedicated iLO management module

Observe the following rules and limitations when installing an dedicated iLO management port module:
If a dedicated iLO management port module is installed in the server:
The server can only connect to a network through the dedicated iLO management port module.
The server cannot be accessed through the chassis management module.
If using the chassis management module iLO ports or the dedicated iLO management port module to
connect to a network, the network must operate at a speed of 1 Gb/s. The server cannot connect to
the network if the network is operating at a speed of 10/100 Mb/s or 10 Gb/s.
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the Hewlett Packard Enterprise website.

Removing the dedicated iLO management module

Procedure
1.
Back up all server data.
2.
Power down the server .
3.
Disconnect all peripheral cables from the server front panel.
4.
Remove the server from the chassis.
5.
Place the server on a sturdy, level surface.
6.
Remove the access panel.
7.
Remove the air baffle.
8.
Remove the drive cage assembly.
9.
If installed in slot 10, remove the expansion board.
10. Remove the failed dedicated iLO management module.
68
Dedicated iLO management module

Hide quick links: