Finish the installation by completely tightening the screws in the same sequence.
b.
Install the fans.
12.
Install all components removed from the failed system board.
13.
Connect all cables disconnected from the failed system board.
14.
Install the PCI riser cages.
15.
Install the access panel.
16.
Do one of the following:
17.
Slide the server into the rack.
o
Install the server into the rack.
o
Connect each power cord to the server.
18.
Connect each power cord to the power source.
19.
Power up the server.
20.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access UEFI System Utilities.
1.
Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options
2.
> Advanced System ROM Options > Serial Number, and then press the Enter key.
Enter the serial number and press the Enter key. The following message appears:
3.
The serial number should only be modified by qualified service personnel.
This value should always match the serial number located on the chassis.
Press the Enter key to clear the warning.
4.
Enter the serial number and press the Enter key.
5.
Select Product ID. The following warning appears:
6.
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
Enter the product ID and press the Enter key.
7.
Press the F10 key to confirm exiting System Utilities. The server automatically reboots.
8.
Removal and replacement procedures 75