1.
Press the MODE button while in normal operating mode to switch
to "configuration layer" mode.
Use ▲▼ to select the configuration layer for the parameter you
2.
wish to set.
Press MODE to confirm. Press ▲▼ to select the particular pa-
3.
rameter.
Press MODE to confirm. Press ▲▼ to adjust the parameter val-
4.
ue.
Press MODE again to end. Press ▲▼ to select
5.
6.
Now use MODE to either apply the changes you have made to the
SAVE
settings [
END
[
] . After that, the display panel will resume showing the
temperature reading.
The following parameters are important for initial set-up prior to first-time
operation. See Chapter 6 for a comprehensive list of all adjustable pa-
rameters.
Parameter
EPS.1
AO1._
AO1.~
AO1.4
AO1.T
NOTE !
Key lock may have been activated at the terminal. When selecting
the configuration layer you will be prompted to enter an access
code with
P100
enter
but not change them.
6.7

Setting Emissivity

] or to close without saving these changes
configuration
layer
C001
C010
C010
C010
C100
P000
. To obtain full access to parameter settings,
otherwise you will only be able to view parameters
Operating manual PA
Explanation
Emissivity spectral channel 1
(see chapter 6.7).
Lower limit of temperature span
analogue output Ao1
(see chapter 6.8).
Upper limit of temperature span
analogue output Ao1
(see chapter 6.8).
Hardware configuration of the ana-
logue output 0-20 mA, 4-20 mA
(see chapter 6.8)
Temperature measurement simula-
tion to verify signal transmission
(see chapter 6.9)
16