Details of Operation (Monitor Mode)
Alarm Display
<Notes>
• The battery alarm is kept active until the control power is turned off.
• Other alarms are kept displayed at least one second after the alarm event occurs.
• Alarming criteria cannot be changed.
Display of the load factor
of the regenerative discharge resistor
• Display the load factor of the regenerative discharge resistor as a percentage of the protective
operation level (100%).
• For an external regenerative discharge resistor, Pr6C should be 0 or 1 to display the load factor.
Display of the load factor
• Display the load factor as a percentage of the rated load (100%).
• See "Overload Protection: Time Limiting Characteristic" in Appendix.
A : FAlarm occurred
– : FNo alarms occurred
Over-regeneration alarm: over 85% of the acceptable
consumption of the regenerative discharge resistor
Overload alarm: over 85% of the acceptable load level
Battery alarm: under the acceptable voltage level
Acceptable load factor of the regenerative discharge resistor (unit : %)
Load factor (unit : %)
- App. 62 -