Omron NJ501 Connection Manual page 44

Machine automation controller nj-series; ne1a-series safety network controller
Hide thumbs Also See for NJ501:
Table of Contents

Advertisement

7.5.2.
Checking Data That Are Sent and Received
Confirm that the correct data are sent and received.
Always confirm safety at the destination node before you transfer a user
program, configuration data, setup data, device variables, or values in memory
used for CJ-series Units from the Sysmac Studio.
The devices or machines may perform unexpected operation regardless of the
operating mode of the CPU Unit.
1
Confirm that the online value of
DN00_Status_IN[6] is True (RUN
mode).
2
Confirm that MS LED indicator of
the Safety Network Controller is lit
green.
3
Right-click
the
Control
ler and select Change Mode
- Idle.
Safety
Network
7.Connection Procedure
41